5/24/COM; structural checklist with referenced dependencies
SHA-256: 2490f9a571c1048e0338688fb0536c69b0dcd7aed34f623bb5b735b059e032cd
This is an independent prototype for exploring Portland permitting tools. It is not an official City of Portland service and is not a substitute for the actual permitting process.
For official applications, requirements, payments, and permit status, use Portland Permitting & Development.
183 downloaded chapter PDFs; 1492 distinct section references found in their text. Each snapshot is hashed for change detection and reproducibility.
Downloaded, indexed, interpreted and executable are different states. This index includes cross-references, tables of contents and repealed sections. It is not a complete requirement inventory, a current-law determination, or a percentage of automated review.
5/24/COM; structural checklist with referenced dependencies
SHA-256: 2490f9a571c1048e0338688fb0536c69b0dcd7aed34f623bb5b735b059e032cd
Published guidance; new standard stairs only
SHA-256: ae01d917f31b93a0e166f984aadb2ee5debad1306a59c5b3b5fdc32463a28b27
New escape windows; historical/alteration paths require separate review
SHA-256: 7004a7bfc00fc84a581100dd1a42aa534d256f4ef60c2e365d0570232ca70f51
8/25/COM; intake scope, not technical approval
SHA-256: a46e852073345a20efb8b9771db00f3dd76395fac9ec040acd158ee88415cd18
2026 transition; 2023 construction provisions available through phase-in
SHA-256: 74960b96b497555e98d192e7667b208c1348682a711a24b4803c113b64db628a
Inventory reviewed November 1, 2026
SHA-256: 7e8099fb317bc60a3945f56da773b3fa8e5478eccf5904402c648275276ced13
Effective and mandatory October 1, 2026
SHA-256: b88c55270fcdb3a758b8667965398f1406195c9a1134a7b5e5d9c7e97d32cbd2
R332; effective January 1, 2026
SHA-256: 1f7fbbd249c778cc35ed66a33b886b552c59029ccb59deba513b159e2a9f4494
Table 1-E; effective October 1, 2026; base NEC remains separately required
SHA-256: 9fb530b4a48775dba4eb5512e5dafd7492e4cc1ea52f97c5791bd9dcbd025774
Effective 2023-10-01; selected sections; deleted text excluded
SHA-256: 365be453e5fafed2e565824c28b6d9a79d90d61f02c136affa000a754aaec908
2025 edition; reviewed 2026-11-01
SHA-256: 13b84702b70d6348a9cb1aa5139de989ce58628e82ee4f1448d91cd84a2f341e
Effective 2025-01-01; includes March 4 2025 errata
SHA-256: b417fc4b5693e01f61b1f951ffa8b241386cd3b376ac7fad7bbf9b07e552957d
Revised 2024-05-30
SHA-256: 7e9ba6ac5724a43b98d298468020c9b1117da00122d7eaffde2a407ca1f278b2
2026 OPSC effective 2026-10-01; reviewed selected sections
SHA-256: b4f7b1bec7c37d8438ac022ae5e0152f13a2046baa321ad7f7481b0ea8dff9cc
2023 ORSC; selected R324.4 figures and R324.6 provisions; pages 75–77
SHA-256: 69405088f0b32dedceac5009331d8f27439ce6f1ad6de9838b8b9797f0619b17
Effective October 1, 2024; one identified room/space only
SHA-256: 5a59113fa32e0d4f5f04bd3a044760b7ba31e55d13dc7205581d3473b9585e09
Selected pages 110-23 through 110-27, 1/1/25; source snapshot 2026-09-09
SHA-256: 5818eabec42072bc474cfdedbe041ed11e39c59c6aeede983624c97f1bc3269e
Page 248-4, 8/10/20; source snapshot 2026-09-09
SHA-256: ad9260512a894e31bb979332178c16f3625ab5c1227d022e00896630d1a2c8a1
Selected pages 205-1 through 205-5: 10/1/24. Eligibility compared with replacement pages 205-1/2 in Update 214 (6/1/25).
SHA-256: dd032db9cea98bb8945a695a946b817d6a15b5f912a8d4aa43a487ccce329bc3
Public text reviewed 2026-09-09
No frozen byte snapshot linked to this source yet.
Relevant pages 110-48/49: 3/1/25 and 1/1/25
SHA-256: 5818eabec42072bc474cfdedbe041ed11e39c59c6aeede983624c97f1bc3269e
Live guidance reviewed 2026-09-09; not a complete structural code
No frozen byte snapshot linked to this source yet.
Applicability and referenced chapters require project-specific review
No frozen byte snapshot linked to this source yet.
Edition selection depends on project, discipline and application date
No frozen byte snapshot linked to this source yet.
130 executable checks; 29 explicit dependencies still missing. These are scoped checklist/guidance checks, not complete specialty-code coverage.
Download the machine-readable rule inventory440-5952 Part III: Residential rooftop PV structural prescriptive checklist only; no electrical, fire-pathway or complete structural approval.
Inputs: manufacturedDwelling (none), conventionalLightFrame (none)
440-5952 Part III: Residential rooftop PV structural prescriptive checklist only; no electrical, fire-pathway or complete structural approval.
Inputs: siteGravityWindDesignDocumented (none), manufacturerInstallationDocumented (none)
440-5952 Part III: Residential rooftop PV structural prescriptive checklist only; no electrical, fire-pathway or complete structural approval.
Inputs: groundSnowPsf (psf), windExposure (none)
440-5952 Part III: Residential rooftop PV structural prescriptive checklist only; no electrical, fire-pathway or complete structural approval.
Inputs: framingType (none), framingSpacingIn (in)
R324.4.1 Exception 1.4–1.6: Residential rooftop PV structural prescriptive checklist only; no electrical, fire-pathway or complete structural approval.
Inputs: framingType (none)
Referenced rafter provisions require the adopted full-code text and span/grade geometry. The checklist alone cannot verify this dependency.
440-5952 Part III: Residential rooftop PV structural prescriptive checklist only; no electrical, fire-pathway or complete structural approval.
Inputs: roofCover (none), roofLayers (count)
440-5952 Part III: Residential rooftop PV structural prescriptive checklist only; no electrical, fire-pathway or complete structural approval.
Inputs: arrayDeadLoadPsf (psf)
440-5952 Part III: Residential rooftop PV structural prescriptive checklist only; no electrical, fire-pathway or complete structural approval.
Inputs: moduleTopAboveRoofIn (in)
Figures R324.4.1(2)–(3): Documented support configuration only. Rafter/truss capacity, blocking design and manufacturer-specific fastener capacities remain separate dependencies.
Inputs: attachmentMethod (none), continuousSupportRail (none), prefabricatedStandoff (none), supportedOnRafterTrussOrBlocking (none)
440-5952 Part III: Residential rooftop PV structural prescriptive checklist only; no electrical, fire-pathway or complete structural approval.
Inputs: attachmentMethod (none), directToFramingOrBlocking (none), attachmentMaxSpacingIn (in), groundSnowPsf (psf), attachmentEdgeDistanceFt (ft), basicWindMph (mph), windExposure (none)
440-5952 Part III: Residential rooftop PV structural prescriptive checklist only; no electrical, fire-pathway or complete structural approval.
Inputs: attachmentMethod (none), directToStandingSeam (none), clampAlongSeamIn (in), clampMinimumAlongSeamIn (in), clampAcrossSeamIn (in), clampAllowableUpliftLb (lb)
440-5952 Part III: Residential rooftop PV structural prescriptive checklist only; no electrical, fire-pathway or complete structural approval.
Inputs: attachmentMethod (none), panelMaterial (none), panelGauge (gauge), panelWidthIn (in), screwNumber (count), screwSpacingIn (in), sheathingNominalIn (in), woodStructuralPanel (none), sheathing8dNails (none), sheathingEdgeNailingIn (in), sheathingFieldNailingIn (in)
440-5952 Part III: Residential rooftop PV structural prescriptive checklist only; no electrical, fire-pathway or complete structural approval.
Inputs: attachmentMethod (none)
440-5952 Part V; R324.6: Residential rooftop PV structural prescriptive checklist only; no electrical, fire-pathway or complete structural approval.
Inputs: None implemented
Selected access dimensions are implemented. Complete roof geometry, all edges/ridges/openings and the connectivity of every required pathway still need independent plan reconciliation.
440-5952 introductory scope: Residential rooftop PV structural prescriptive checklist only; no electrical, fire-pathway or complete structural approval.
Inputs: None implemented
Circuit, conductor, equipment listing, grounding/bonding, disconnect and interconnection checks require the adopted electrical code and equipment data.
R324.6.8.4.2: 2023 ORSC Oregon solar amendments, reviewed November 4, 2026. Supplied roof geometry, feature inventory and product details require verification; selected checks do not establish full structural or fire access compliance.
Inputs: roofSlopeRatio (ratio), racewayInPathway (none)
R324.6.3–5, 7: 2023 ORSC Oregon solar amendments, reviewed November 4, 2026. Supplied roof geometry, feature inventory and product details require verification; selected checks do not establish full structural or fire access compliance.
Inputs: egressUnrestricted (none), lightVentilationUnrestricted (none), roofFeaturesFunctional (none), roofDrainageUnobstructed (none)
R324.6.6: 2023 ORSC Oregon solar amendments, reviewed November 4, 2026. Supplied roof geometry, feature inventory and product details require verification; selected checks do not establish full structural or fire access compliance.
Inputs: serviceableRoofEquipment (none), equipmentClearanceIn (in)
R324.6.7: 2023 ORSC Oregon solar amendments, reviewed November 4, 2026. Supplied roof geometry, feature inventory and product details require verification; selected checks do not establish full structural or fire access compliance.
Inputs: roofValleyPresent (none), supportValleyDistanceIn (in)
R324.6.8.1: 2023 ORSC Oregon solar amendments, reviewed November 4, 2026. Supplied roof geometry, feature inventory and product details require verification; selected checks do not establish full structural or fire access compliance.
Inputs: solarAccessPath (none), roofSlopeRatio (ratio), pathwaySideCount (count), pathwayMinimumWidthIn (in), pathwaysStructurallySupported (none), bottomEdgeUsedAsPathway (none)
R324.6.8.1 exception 1: 2023 ORSC Oregon solar amendments, reviewed November 4, 2026. Supplied roof geometry, feature inventory and product details require verification; selected checks do not establish full structural or fire access compliance.
Inputs: solarAccessPath (none), arrayPlanAreaSqFt (sq_ft), totalRoofPlanAreaSqFt (sq_ft), maximumArrayDimensionFt (ft), roofSlopeRatio (ratio), intersectingAdjacentRoofPlane (none)
R324.6.8.1 exceptions 1.1–1.2: 2023 ORSC Oregon solar amendments, reviewed November 4, 2026. Supplied roof geometry, feature inventory and product details require verification; selected checks do not establish full structural or fire access compliance.
Inputs: solarAccessPath (none), arrayPlanAreaSqFt (sq_ft), totalRoofPlanAreaSqFt (sq_ft), ridgeEachSideClearIn (in), ridgeToEaveWidthIn (in), ridgeToEaveStructurallySupported (none)
R324.6.8.1 exception 2: 2023 ORSC Oregon solar amendments, reviewed November 4, 2026. Supplied roof geometry, feature inventory and product details require verification; selected checks do not establish full structural or fire access compliance.
Inputs: solarAccessPath (none), nonhabitableAccessoryStructure (none), habitableSeparationIn (in), separatingAssemblyHours (none)
R324.6.8.1 exception 3 / R324.6.9: 2023 ORSC Oregon solar amendments, reviewed November 4, 2026. Supplied roof geometry, feature inventory and product details require verification; selected checks do not establish full structural or fire access compliance.
Inputs: solarAccessPath (none)
Townhouse fire-separation history and permission to treat buildings as one structure, or an approved alternative design, require an authoritative project determination.
R324.6.8.2–2.1: 2023 ORSC Oregon solar amendments, reviewed November 4, 2026. Supplied roof geometry, feature inventory and product details require verification; selected checks do not establish full structural or fire access compliance.
Inputs: maximumArrayDimensionFt (ft), arrayPlanAreaSqFt (sq_ft), maximumUnbrokenArrayDimensionFt (ft), maximumUnbrokenArrayAreaSqFt (sq_ft), intermediatePathWidthIn (in), maximumDistanceToCutoutFt (ft)
R324.6.8.3–4: Raceway exception is implemented only for flat roofs; positive slopes at or below 2:12 need a separate interpretation rather than assuming they are flat.
Inputs: solarAccessPath (none), roofValleyPresent (none), pathwayValleyDistanceIn (in), boxesOutsidePathways (none), racewayInPathway (none), roofSlopeRatio (ratio), crossingRacewayBridged (none)
Portland residential stair guidance: New straight residential stairs; special configurations and existing stair exceptions are separate.
Inputs: stairPath (none)
Portland residential stair guidance: New straight residential stairs; special configurations and existing stair exceptions are separate.
Inputs: stairPath (none), widthAboveRailsIn (in)
Portland residential stair guidance: New straight residential stairs; special configurations and existing stair exceptions are separate.
Inputs: stairPath (none), headroomIn (in)
Portland residential stair guidance: New straight residential stairs; special configurations and existing stair exceptions are separate.
Inputs: stairPath (none), riserMinIn (in), riserMaxIn (in)
Portland residential stair guidance: New straight residential stairs; special configurations and existing stair exceptions are separate.
Inputs: stairPath (none), treadMinIn (in), treadMaxIn (in)
Portland residential stair guidance: New straight residential stairs; special configurations and existing stair exceptions are separate.
Inputs: stairPath (none), nosingMinIn (in), nosingMaxIn (in)
Portland residential stair guidance: New straight residential stairs; special configurations and existing stair exceptions are separate.
Inputs: stairPath (none), riserCount (count), handrailPresent (none), handrailMinHeightIn (in), handrailMaxHeightIn (in), handrailWallClearanceIn (in), handrailProjectionIn (in), handrailContinuous (none), handrailReturns (none)
Portland residential stair guidance: New straight residential stairs; special configurations and existing stair exceptions are separate.
Inputs: stairPath (none), riserCount (count), gripType (none), gripDiameterIn (in), gripPerimeterIn (in), gripCrossSectionIn (in)
Portland residential stair guidance: New straight residential stairs; special configurations and existing stair exceptions are separate.
Inputs: stairPath (none), maximumDropWithin36In (in), stairGuardPresent (none), stairGuardHeightIn (in), stairGuardOpeningIn (in), stairTriangleOpeningIn (in)
Portland residential stair guidance: New straight residential stairs; special configurations and existing stair exceptions are separate.
Inputs: stairPath (none)
Landing/door geometry, flight rise limits, structural connections, accessibility and exceptions require additional adopted provisions and project geometry.
Portland residential windows: emergency escape: New residential escape windows; no historical or alteration exceptions.
Inputs: windowPath (none), measurementBasis (none)
Portland residential windows: emergency escape: New residential escape windows; no historical or alteration exceptions.
Inputs: windowPath (none), clearWidthIn (in), clearHeightIn (in), clearAreaSqFt (sq_ft)
Portland residential windows: emergency escape: New residential escape windows; no historical or alteration exceptions.
Inputs: sillAboveFloorIn (in)
Portland residential windows: emergency escape: New residential escape windows; no historical or alteration exceptions.
Inputs: opensFromInside (none), requiresKey (none), requiresTool (none), requiresSpecialKnowledge (none)
Portland residential windows: emergency escape: New residential escape windows; no historical or alteration exceptions.
Inputs: sillBelowGround (none), wellClearWidthIn (in), wellClearProjectionIn (in), windowFullyOpensInWell (none)
Portland residential windows: emergency escape: Ladder path only. A step design outside this check needs separate assessment.
Inputs: sillBelowGround (none), wellDepthIn (in), wellAccessType (none), wellLadderPermanent (none), wellLadderRungWidthIn (in), wellLadderRungSpacingIn (in), wellLadderWallClearanceIn (in), wellLadderProjectionIn (in), wellLadderFullHeight (none), wellAccessObstructsWindow (none)
Portland residential windows: emergency escape: New residential escape windows; no historical or alteration exceptions.
Inputs: sillBelowGround (none), wellCoverPresent (none), wellCoverRemovableInside (none), wellCoverClearAreaSqFt (sq_ft)
Portland residential windows: emergency escape: New residential escape windows; no historical or alteration exceptions.
Inputs: None implemented
R310 discharge paths, opening-control devices, fall protection and historical exceptions are not settled by aperture measurements.
Portland residential stair guidance: Published spiral dimensions only; other stair, guard and egress requirements remain unverified.
Inputs: stairPath (none), spiralWidthIn (in), headroomIn (in), spiralTreadAt12In (in), riserMaxIn (in), spiralTreadsIdentical (none)
Portland residential stair guidance: Winder tread and consistency checks only; other stair, guard and egress requirements remain unverified.
Inputs: stairPath (none), winderNarrowestIn (in), winderWalklineMinIn (in), winderWalklineMaxIn (in), riserMinIn (in), riserMaxIn (in)
Portland residential stair guidance: Guard at an adjacent landing; landing geometry and structural capacity remain separate.
Inputs: stairPath (none), landingDropWithin36In (in), landingGuardPresent (none), landingGuardHeightIn (in), landingGuardOpeningIn (in)
Light and ventilation: Natural ventilation route only. Mechanical alternatives, daylight and other room requirements remain separate.
Inputs: spaceType (none), ventilationPath (none), roomFloorAreaSqFt (sq_ft), openableExteriorAreaSqFt (sq_ft), ventilationOpensOutside (none)
R332.1 / Appendix AQ notice: 2023 ORSC R332 sleeping loft amendment only; small-home, complete R311 egress and NFPA 13D design are separate.
Inputs: dwellingAreaSqFt (sq_ft), loftDepthFt (ft), loftAreaSqFt (sq_ft), permanentEgress (none), openToRoom (none)
R332.2(1): 2023 ORSC R332 sleeping loft amendment only; small-home, complete R311 egress and NFPA 13D design are separate.
Inputs: loftAreaSqFt (sq_ft)
R332.2(2): 2023 ORSC R332 sleeping loft amendment only; small-home, complete R311 egress and NFPA 13D design are separate.
Inputs: loftAreaSqFt (sq_ft), loftAreaAboveSevenFtSqFt (sq_ft)
R332.3 / R332.5.1: 2023 ORSC R332 sleeping loft amendment only; small-home, complete R311 egress and NFPA 13D design are separate.
Inputs: clearHeightBelowFt (ft), loftMinimumHeightFt (ft), accessMinimumHeightFt (ft)
R332.1.1: 2023 ORSC R332 sleeping loft amendment only; small-home, complete R311 egress and NFPA 13D design are separate.
Inputs: nfpa13dDesignDocumented (none), loftSprinklerCoverage (none), receivingRoomSprinklerCoverage (none)
R332.4 exception: 2023 ORSC R332 sleeping loft amendment only; small-home, complete R311 egress and NFPA 13D design are separate.
Inputs: loftAreaSqFt (sq_ft), receivingRoomAreaSqFt (sq_ft), otherLoftsAndMezzanines (count)
R332.4 / R325.3: 2023 ORSC R332 sleeping loft amendment only; small-home, complete R311 egress and NFPA 13D design are separate.
Inputs: otherLoftsAndMezzanines (count)
R325.3 aggregate-area provisions and all compartment loft/mezzanine geometry must be reviewed; the single-loft exception does not apply.
R332.5.2.1: 2023 ORSC R332 sleeping loft amendment only; small-home, complete R311 egress and NFPA 13D design are separate.
Inputs: loftAccess (none), loftStairAboveRailIn (in), loftStairBelowRailIn (in)
The published amendment pairs 20 inches with 610 mm for below-rail width; these are inconsistent. Obtain authoritative errata or interpretation before automatically determining this dimension.
R332.5.2.2: A single paired rise/tread value only represents a uniform segment. Nonuniform segments need individual measurements rather than a blanket failure.
Inputs: loftAccess (none), loftStairSegmentUniform (none)
R332.5.2.2: 2023 ORSC R332 sleeping loft amendment only; small-home, complete R311 egress and NFPA 13D design are separate.
Inputs: loftAccess (none), loftRiserIn (in), loftTreadIn (in), loftStairSegmentUniform (none)
R332.5.2.3: 2023 ORSC R332 sleeping loft amendment only; small-home, complete R311 egress and NFPA 13D design are separate.
Inputs: loftAccess (none), loftLandingDepthIn (in)
R332.5.3.1–2: 2023 ORSC R332 sleeping loft amendment only; small-home, complete R311 egress and NFPA 13D design are separate.
Inputs: loftAccess (none), loftRungWidthIn (in), loftRungSpacingMinIn (in), loftRungSpacingMaxIn (in), loftRungCapacityLb (lb), loftLadderAngleDegrees (degrees)
R332.1.1 / R332.5 / R311: 2023 ORSC R332 sleeping loft amendment only; small-home, complete R311 egress and NFPA 13D design are separate.
Inputs: loftAccess (none)
Actual NFPA 13D design/capacity, remaining R311 egress and landing requirements, and alternating-tread provisions require the referenced standards and full project evidence.
110.26(C)(3): Selected 2026 OESC amended provisions only. Listing authenticity, base NEC, design calculations and all equipment/door discovery remain separate.
Inputs: electricalOccupancy (none), equipmentAmps (amps), containsControlOrOvercurrent (none), doorServesWorkingSpace (none), doorDistanceFt (ft), doorOpeningDegrees (degrees), doorOpensWithEgress (none), exitHardware (none), hardwareUL305 (none), hardwareUL10C (none), doorLeafWidthIn (in), actuatingLengthIn (in), unlatchingForceLb (lb), balancedDoor (none), pushPadHardware (none), pushPadFromLatchIn (in)
110.26(D): Selected 2026 OESC amended provisions only. Listing authenticity, base NEC, design calculations and all equipment/door discovery remain separate.
Inputs: equipmentType (none), equipmentIndoors (none), workingSpaceAverageFootcandles (footcandles), allLightingAutomaticOnly (none)
110.22(A): Selected 2026 OESC amended provisions only. Listing authenticity, base NEC, design calculations and all equipment/door discovery remain separate.
Inputs: electricalOccupancy (none), isDisconnect (none), purposeEvident (none), purposeMarked (none), circuitSourceEvident (none), circuitSourceMarked (none), markingDurable (none)
2026 NEC / Oregon Table 1-E: Selected 2026 OESC amended provisions only. Listing authenticity, base NEC, design calculations and all equipment/door discovery remain separate.
Inputs: None implemented
The full base NEC, other amendments, equipment ratings, available fault current, circuit topology, protection, conductor sizing, grounding/bonding and product listing evidence are not validated by these selected checks.
408.3: A flow rating at a different pressure does not establish the required 80 psi rating. Supply the correct product rating rather than infer a violation from an incomparable test.
Inputs: plumbingType (none), ratingPressurePsi (psi)
408.3: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), ratedFlowGpm (gpm), ratingPressurePsi (psi)
420.3: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), ratedFlowGpm (gpm), sprayForceOz (oz_force), integralAutomaticShutoff (none)
707.9: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), pipeDiameterIn (in), frontClearWidthIn (in), frontClearDepthIn (in)
707.9: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), pipeDiameterIn (in), frontClearWidthIn (in), frontClearDepthIn (in)
707.9: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), underfloor (none), verticalAccessIn (in), horizontalAccessIn (in), extendedToFloorOrOutside (none)
310.9: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), femalePlastic (none), parallelThread (none), maleMetallic (none)
605.15: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), unionStandard (none)
604.13: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), connectorMaterial (none), connectorLengthIn (in)
604.13: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), flexibleConnector (none), connectorStandardDocumented (none)
608.2 / 608.3: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), securelyFastened (none)
608.2 / 608.3: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none)
Tank sizing, listing and manufacturer-specific installation require additional source and project calculations; secure fastening alone does not establish compliance.
603.5.6: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), pumpingConnection (none), chemicalInjection (none), backflowDevice (none)
603.5.6.3: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), chemicalInjection (none), backflowDevice (none)
603.5.6.1–2: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), pumpingConnection (none)
Device-choice checks now distinguish upstream backpressure and downstream potable pumps. Complete actual pump/device connectivity, installation clearances, listing and testing remain to be verified.
309.5: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), pipeDiameterIn (in), deadLegLengthIn (in), accessibleFlushing (none)
708.1: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), slopeInPerFt (in_per_ft), uniformTowardDisposal (none), reducedSlopeClaimed (none)
708.1 exception: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), reducedSlopeClaimed (none)
The reduced-slope path requires impracticality, qualifying building-drain diameter, minimum slope and prior Building Official approval. A checkbox cannot grant that approval.
1002.3: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), pipeDiameterIn (in), directionChangeDegrees (degrees), cleanoutProvided (none)
1002.3 exception: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none), pipeDiameterIn (in), directionChangeDegrees (degrees), cleanoutProvided (none)
706.3 / 908–911: Selected 2026 OPSC provisions. Supplied product specifications and site facts require verification; this is not full plumbing design or installation approval.
Inputs: plumbingType (none)
Distance, load and turn checks do not establish fitting compliance or wet, circuit, combination or engineered vent-system eligibility. Those system paths require additional checks.
Table 702.1(1): 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), pipeDiameterIn (in)
706.3: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), horizontalDirectionChange (none), horizontalFitting (none), equivalentSweepApprovalDocumented (none)
603.5.6.1: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), deviceUpstreamOfBackpressure (none), backflowDevice (none)
603.5.6.2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), deviceDownstreamOfPotablePump (none), backflowDevice (none)
Table 703.2 / 708.1: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), pipeDiameterIn (in), reducedSlopeClaimed (none)
Table 703.2 notes 1–5, 7: Ordinary quarter-inch-per-foot horizontal drainage, excluding trap arms and Appendix C alternatives. Public-lavatory aggregation must be reconciled under note 7 before entering DFU; reduced slope remains a separate approval path.
Inputs: plumbingType (none), pipeDiameterIn (in), connectedDfu (count), waterClosetCount (count), sixUnitTrapCount (count), restrictedSmallPipeFixtureCount (count)
Table 1002.2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), pipeDiameterIn (in), trapArmClass (none)
1002.2 / Table 1002.2 notes 1–3: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), pipeDiameterIn (in), trapArmClass (none), trapArmLengthIn (in), slopeInPerFt (in_per_ft)
1002.4 / 905.5: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), trapArmClass (none), ventOpeningAtOrAboveWeir (none)
Table 702.1(1): 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), pipeDiameterIn (in), connectedDfu (count), selfServiceLaundry (none)
904.1–2 / Table 703.2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), pipeDiameterIn (in), upsizedLengthExceptionClaimed (none)
904.1: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), pipeDiameterIn (in), servedDrainDiameterIn (in)
904.1–2 / Table 703.2 notes 3, 6: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), pipeDiameterIn (in), connectedDfu (count), waterClosetCount (count), sixUnitTrapCount (count), ventLengthFt (ft), horizontalVentLengthFt (ft)
905.1: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), noDropsOrSags (none), drainsBackByGravity (none)
905.2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), horizontalDrainConnection (none), invertAboveDrainCenterline (none), downstreamOfTrap (none)
905.3: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), structuralRiseExceptionClaimed (none), riseAboveFloodRimIn (in)
905.3: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), structuralRiseExceptionClaimed (none)
Confirm actual structural obstruction and drainage-grade fittings/materials. The ordinary six-inch rule cannot decide this exception.
906.1: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), heightAboveRoofIn (in), verticalSurfaceDistanceIn (in)
906.2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), nearestOpeningDistanceFt (ft), heightAboveOpeningsFt (ft)
906.2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), lotLineDistanceFt (ft)
906.3: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), usedRoofDistanceFt (ft), heightAboveUsedRoofFt (ft), securelyStayed (none)
804.1: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), standpipeAboveWeirIn (in), trapAboveFloorIn (in)
703.1–2 / Table 703.2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), pipeDiameterIn (in), connectedDfu (count), waterClosetCount (count), sixUnitTrapCount (count), restrictedSmallPipeFixtureCount (count)
Table 703.2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), pipeDiameterIn (in)
703.1–2 / Table 703.2: Table lengths for 1.25–8 inch vertical drains. Blank 10/12-inch length cells and offset-stack length interpretations remain unresolved; this is not a high-rise stack approval.
Inputs: plumbingType (none), pipeDiameterIn (in), verticalDrainLengthFt (ft)
907.1–2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none)
A passing vertical capacity calculation does not establish story count, required parallel stack, yoke connections or offset-stack behavior. Supply the separately assessed stack-relief model and verify the complete system.
901.2 / 905.1–5: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), dryVentConnectivityValid (none)
904.1: Area comparison cancels pi/4. Sewer requirement must be independently established. Shared terminals count once; upstream air-obstructing devices exclude the entire affected terminal from this conservative ordinary path.
Inputs: plumbingType (none), eligibleVentDiameterSquaredSum (none), requiredSewerDiameterSquared (none)
Table 610.3 / 610.10: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), individualFixtureBranch (none), fixtureBranchMinimumKnown (none), requiredFixtureBranchIn (in), pipeDiameterIn (in)
907.1: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), stackStoryCount (count), parallelVentPresent (none), parallelVentUndiminished (none), parallelVentLowestConnection (none)
907.1: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), yokeDiameterIn (in), stackDrainDiameterIn (in), stackVentDiameterIn (in)
907.2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), yokeConnectionAboveFloorIn (in), yokeDrainWyeBelowBranch (none)
907.1–2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none)
Each fifth-floor connection counted from the uppermost fixture drain must be reconciled against a complete floor/branch/parallel-stack drawing. Scalar yoke measurements do not establish this topology.
909.1: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), islandTrapAboveFloor (none), islandVentAsHighAsPossible (none), islandLoopHeightIn (in), islandDrainboardHeightIn (in)
909.1: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), islandReturnWyeImmediate (none), islandFootWyeBelowFloor (none), islandFootNearestPartition (none), islandDrainageFittingsBelowFloor (none), islandFootCleanoutAccessible (none), islandUpstreamOtherFixtures (none), islandFootSlopeInPerFt (in_per_ft), islandReturnBend (none)
909.1 / 904 / 1002: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none)
A conventional upward-only dry-vent graph cannot represent an island return loop. Bind loop, return, foot vent, trap and roof connection, and assess sizing before accepting the full method.
911.1: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), circuitFixtureCount (count), circuitOutletClass (none), circuitTrapArmsHorizontal (none)
911.2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), pipeDiameterIn (in), circuitVentBetweenUpperTraps (none), circuitVentReceivesWaste (none)
911.4: Maximum circuit grade only; Chapter 7 minimum slope and total-branch capacity must also be assessed.
Inputs: plumbingType (none), slopeInPerFt (in_per_ft), uniformTowardDisposal (none)
911.3–3.1: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), waterClosetCount (count), circuitStackReceivesUpperWaste (none), circuitReliefDiameterIn (in), circuitReliefVerticalBetweenStackAndLastTrap (none)
911.3.2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), circuitReliefReceivesWaste (none), circuitReliefOnlyOneTwoDfuFixtures (none), circuitReliefDfu (count)
911.1–5 / Table 703.2 / Table 1002.2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none)
Requires independently reconciled trap arms, circuit/relief connections, additional fixtures and parallel/continuous branch boundaries. Individual scalar checks do not validate a circuit-vent system.
608.2 / 610.2 / 610.7–8: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), availablePressurePsi (psi), designSourcePressurePsi (psi), minimumSourcePressurePsi (psi), elevationRiseFt (ft), elevationDropFt (ft), deviceLossPsi (psi), allDeviceLossesIncluded (none), pressureRegulatorPresent (none), regulatorSettingPsi (psi)
610.4 / 610.7–10 / Table 610.4: Table 610.4 only. Continuous demands need separate flow addition; parallel systems need listing/velocity design. Pressure between 45 and 46 psi requires review rather than silently selecting a band. Complete pressure-loss evidence and a reconciled fixture schedule remain necessary.
Inputs: plumbingType (none), availablePressurePsi (psi), meterDiameterIn (in), pipeDiameterIn (in), remoteOutletLengthFt (ft), continuousDemandPresent (none), parallelDistributionSystem (none), fixtureScheduleReconciled (none)
Table 610.4 / 610.8–9: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), availablePressurePsi (psi), meterDiameterIn (in), pipeDiameterIn (in), remoteOutletLengthFt (ft), connectedWsfu (count)
610.8(6) / Table 610.4 note 2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), pipeDiameterIn (in), waterPipeRole (none)
610.12 / Appendix A: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none)
Table capacity does not establish non-copper material-specific velocity limits, terminal pressure/flow, thermal expansion or manufacturer/listing compliance. Supply those calculations and product data for the remaining design checks.
908.2 / 908.2.1 / 908.2.5: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), sameFloorBathroomGroup (none), onlyBathroomGroupOnBranch (none), dryVentedFixture (none), upstreamWetFixtureCount (count)
908.2.2: Published bands specify four or fewer and five or more DFU. Intermediate fractional loads require interpretation; do not silently assign the smaller diameter.
Inputs: plumbingType (none), connectedDfu (count)
908.2.2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), connectedDfu (count), pipeDiameterIn (in)
908.2.4–5: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), waterClosetDownstream (none), additionalFixturesDownstreamAndVented (none)
908.1: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), wetFixtureCount (count), onlyOneTwoDfuFixtures (none), allWetFixturesSameStory (none), wetVentLengthFt (ft)
908.1.1: Each section between consecutive inlet levels must be assessed separately with its upper fixture minimum waste and cumulative section load. This selected one/two-DFU, up-to-four-fixture path does not prove connected wet-vent topology.
Inputs: plumbingType (none), connectedDfu (count), upperFixtureMinimumWasteIn (in), pipeDiameterIn (in)
908.1.1–2 / 908.2.1–3: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none)
Connect each actual trap arm and dry vent to its system and reconcile total loads, minimum dry-vent size, trap size, vent rise/takeoff and openings. Each vertical section must also pass its one-pipe-size increase calculation. Supplied system declarations alone do not prove connectivity.
610.12.1–2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), copperTubeOrFittings (none), waterTemperatureClass (none), designFlowGpm (gpm), minimumInternalDiameterIn (in)
610.12.1–2: 2026 OPSC selected sizing and vent requirements. Confirmed project measurements and complete fixture schedules are required. A passing check does not validate the entire plumbing system.
Inputs: plumbingType (none), copperTubeOrFittings (none), waterTemperatureClass (none), designFlowGpm (gpm), minimumInternalDiameterIn (in)
C406.4.1: Selected published mechanical provisions only. Test specifications do not perform or witness a physical pressure test; full ventilation, equipment and fuel-gas design remain separate.
Inputs: mechanicalType (none), servicePressureInWc (in_wc), weldedPiping (none), lpNfpa54Path (none), testPressurePsi (psi), holdMinutes (minutes), noPerceptibleDrop (none)
C406.4.1: Selected published mechanical provisions only. Test specifications do not perform or witness a physical pressure test; full ventilation, equipment and fuel-gas design remain separate.
Inputs: mechanicalType (none), servicePressureInWc (in_wc), weldedPiping (none), lpNfpa54Path (none), testPressurePsi (psi), holdMinutes (minutes)
C406.4.1: Selected published mechanical provisions only. Test specifications do not perform or witness a physical pressure test; full ventilation, equipment and fuel-gas design remain separate.
Inputs: mechanicalType (none), servicePressureInWc (in_wc), weldedPiping (none), lpNfpa54Path (none)
Published errata specifies under 14 and exceeding 14 inches w.c.; exactly 14 for nonwelded piping needs authoritative clarification.
C406.4.1 exception: Selected published mechanical provisions only. Test specifications do not perform or witness a physical pressure test; full ventilation, equipment and fuel-gas design remain separate.
Inputs: mechanicalType (none), servicePressureInWc (in_wc), weldedPiping (none), lpNfpa54Path (none)
NFPA 54 testing, inspection and purging alternative has not been encoded; selecting it cannot pass the ordinary pressure-test rules.
507.2.11: Selected published mechanical provisions only. Test specifications do not perform or witness a physical pressure test; full ventilation, equipment and fuel-gas design remain separate.
Inputs: mechanicalType (none)
An approved automatic fire suppression system complying with the Building Code is required. The errata deletes the obsolete 904.12 reference, not the suppression requirement; approval and full design cannot be inferred.
BOD 19-08 conditions 1–6: Checks only the Portland BOD 19-08 louver alternative. All other OMSC requirements remain; alternatives failing these conditions require appeal rather than automatic rejection of the entire project.
Inputs: mechanicalType (none), portlandJurisdictionConfirmed (none), louverAtExteriorPlane (none), ventToLouverIn (in), louverSpacingIn (in), finAngleDegrees (degrees), backdraftDamper (none), multipleAdjacentVents (none), continuousVentSeparation (none), separationMatchesMaterialGauge (none), cleanoutAccessible (none), cleanoutLocationAndMethod (none), otherScreening (none)
E301.3(a) / 6.4.3.4.5: Selected Oregon modifications only, for buildings under the OSSC. Base ASHRAE 90.1 scope, exceptions, design and commissioning remain separate. Recorded specifications do not verify installed performance.
Inputs: energyType (none), servedGarageSections (count), motorNameplateHp (hp), separateSectionSystems (none), automaticContaminantControl (none), minimumAirflowRatio (ratio), halfFlowPowerRatio (ratio)
E301.3(a) exception: Tests only the published exception to 6.4.3.4.5. The no-heating/no-cooling condition is deleted in Oregon. Section 404 and all other applicable mechanical requirements remain.
Inputs: energyType (none), servedGarageSections (count), motorNameplateHp (hp)
E301.3(a) / OMSC 404: Selected Oregon modifications only, for buildings under the OSSC. Base ASHRAE 90.1 scope, exceptions, design and commissioning remain separate. Recorded specifications do not verify installed performance.
Inputs: energyType (none)
OMSC 404 design, contaminant thresholds and commissioning are not fully encoded. Passing energy ratios or the small-system exception does not verify ventilation adequacy.
E301.3(e) / 6.5.8.3: Selected Oregon modifications only, for buildings under the OSSC. Base ASHRAE 90.1 scope, exceptions, design and commissioning remain separate. Recorded specifications do not verify installed performance.
Inputs: energyType (none), spaceFloorAreaSqFt (sq_ft), spotHeatedAreaSqFt (sq_ft), overheadRadiant (none), enclosedUnconditionedSpace (none)
E301.3(e) / 6.4.3.3.1(b),(c): Selected Oregon modifications only, for buildings under the OSSC. Base ASHRAE 90.1 scope, exceptions, design and commissioning remain separate. Recorded specifications do not verify installed performance.
Inputs: energyType (none)
Automatic control requirements referenced in 6.4.3.3.1(b) or (c), space classification and complete base-code applicability need separate review.
E301.3(d) / 6.5.6.1.1: Selected Oregon modifications only, for buildings under the OSSC. Base ASHRAE 90.1 scope, exceptions, design and commissioning remain separate. Recorded specifications do not verify installed performance.
Inputs: energyType (none), individualNontransientDwelling (none), requiredContinuousCfm (cfm), outdoorAirEnergyRecovery (none)
E301.3(d) / 6.5.6.1.1–2: Selected Oregon modifications only, for buildings under the OSSC. Base ASHRAE 90.1 scope, exceptions, design and commissioning remain separate. Recorded specifications do not verify installed performance.
Inputs: energyType (none)
The remaining base-section provisions, required-rate calculation and multi-unit systems need separate review. The amendment deletes the displayed 50% enthalpy sentence; it is not encoded as an active Oregon requirement.
E301.5(a) / 9.1.1.3.1(a): Selected Oregon modifications only, for buildings under the OSSC. Base ASHRAE 90.1 scope, exceptions, design and commissioning remain separate. Recorded specifications do not verify installed performance.
Inputs: energyType (none), existingWatts (watts), proposedWatts (watts), allowanceExceptionClaimed (none), createsNewSpace (none), altersControls (none)
E301.5(a) / 9.1.1.3.1: Selected Oregon modifications only, for buildings under the OSSC. Base ASHRAE 90.1 scope, exceptions, design and commissioning remain separate. Recorded specifications do not verify installed performance.
Inputs: energyType (none), existingWatts (watts), proposedWatts (watts), allowanceExceptionClaimed (none), createsNewSpace (none), altersControls (none)
New spaces, altered controls and allowance alternatives require the referenced ASHRAE sections and tables, not just a before/after wattage comparison.
E301.5(a) / 9.1.1.3.2: Selected Oregon modifications only, for buildings under the OSSC. Base ASHRAE 90.1 scope, exceptions, design and commissioning remain separate. Recorded specifications do not verify installed performance.
Inputs: energyType (none), existingWatts (watts), proposedWatts (watts), allowanceExceptionClaimed (none), controlsAtLeastExisting (none)
E301.5(a) / 9.1.1.3.2 exception: Selected Oregon modifications only, for buildings under the OSSC. Base ASHRAE 90.1 scope, exceptions, design and commissioning remain separate. Recorded specifications do not verify installed performance.
Inputs: energyType (none), existingWatts (watts), proposedWatts (watts), allowanceExceptionClaimed (none)
Table 9.4.2-2 area-specific allowances must be validated without using base-site allowances; this table path is not yet encoded.
Table 610.3 / 610.9–11: Recomputes fixture supply units and flushometer demand for every pipe in a confirmed supply tree. Applies hose-bibb aggregation, selected separate hot/cold reductions and fixture branch minima. Continuous demand stays in gpm and blocks the current WSFU-only sizing path. Unlisted uses and clinical flushometer classification require review.
703.1–2 / Table 703.2: Confirmed vertical segments carry downstream loads and full contiguous run height. Segment splitting cannot reset length limits. Offset-stack interpretation and complete high-rise relief topology remain unresolved.
901.2 / 904 / 905: Binds each fixture to its trap route and drain connection, checks connected vent paths, rise before offset or convergence, gravity return and undiminished diameters. Accumulates loads and lengths; counts distinct unobstructed terminal areas once. Supplied sewer sizing, actual internal diameters and complete inventory require independent verification. Wet, island and circuit methods are separate paths.
Table 702.1 / Table 703.2 note 7: Private, public and assembly DFU values accumulate through confirmed drainage networks. Public-lavatory branch reduction is applied only to qualifying branches. Missing use classifications, shower head counts or washer context block calculation. Reconciled washer batteries apply six DFU per washer on common pipes while individual drains remain three. Flow schedules support Table 702.2 intermittent and 702.3 continuous loads; intermittent discharge above 50 gpm requires determination. Septic sizing and unlisted classifications remain outside this calculator.
904.1–2 / 1002.2: Validated supplied segments accumulate developed trap-arm and vent lengths, including fitting allowances. The tool checks connectivity, dimensions and current-sheet references; it does not independently discover pipe routes in drawings.
Reviewed 2026-11-01. Residential construction edition selection is separate from mandatory 2026 administration. Available code text is not equivalent to implemented review.
Integrated codebook and amendment summary described as forthcoming by BCD; complete 2024 IRC dependencies also required.
Bounded source-linked provisions only; full base-code, amendments, referenced standards and exceptions remain unreconciled.
Source available. Administration, discretionary approvals and records workflow not fully implemented.
Full structural/occupancy/accessibility review, errata and referenced standards not encoded.
Selected Oregon energy amendments implemented; full ASHRAE construction standard and energy-model validation remain.
NFPA codebook requires an account; full base standard and Oregon amendment reconciliation required.
Selected errata and Portland dryer-louver alternative implemented; full base code, equipment data and sizing/ventilation review remain.
Integrated official text is accessible. Selected 2026 checks implemented; full section reconciliation, system topology and sizing remain unfinished engineering.
Installation standards and project-specific manufacturer instructions not encoded.
Park standards and amendments not encoded.
1492 matching references. Showing the first 50.